Blog

Liquid Ozone – Disinfectant for the 21st Century

liquid ozoneCase Study: TC4 Solutions’ TC 9450 Liquid Ozone Treats Filamentous Bacteria Bulking

In a U.S. wastewater treatment plant, the operators came in one morning to find that the secondary clarifier’s solids levels were slowly approaching the overflow weirs. They ran several tests: TSS (Total Suspended Solids), DO (Dissolved Oxygen), and settlometer. The settling rate after 30 minutes was less than 50 ml in a 1000 ml settlometer. The DO was less than 1.0 mg/l. The TSS in the effluent was over 20 mg/l (The plant normally ran TSS at or below 5 mg/l.). The plant chief operator was immediately notified of these conditions and informed the State Regulatory Agency. This had been an ongoing seasonal problem where excessive amounts of filamentous bacteria were in the mixed liquor. In the past, the plant chief operator would have to take the following actions: 1) feed 30 mg/l of chlorine (300 mg/l of liquid sodium hypochlorite at 12.5% per MGD-250 gal/MGD) for 3 days to the RAS; 2) slow the plant’s effluent discharge (using onsite storage basin); 3) notify the State Regulatory Agency about what’s going on at his plant; 4) after high chlorination start reseeding the mixed liquor; 5) wait for two weeks while the biological system (Mass) was restored; and 6) monitor DO, TSS, and settling rates, hoping things would turn around quickly.

Instead, the chief plant operator tested out a new product, TC 9450 Liquid Ozone. In studies using ozone it talks about the effectiveness of ozone to control filamentous bacteria at a very low dosage (1-5 ppm as gaseous ozone). However, TC 9450 had never been tested in this process or these conditions. So the plant operator decided to start off with 25 mg/l of TC 9450 into the return line to the mixed liquor. They were told to monitor the DO (range 2.0 mg/l to 5.0 mg/l) by using the blowers in the aeration basin. Normally under these conditions, the plant would turn off the blowers, but using TC 9450, the blowers could be kept on.

The next day, the secondary clarifier, which was 10 ft. tall, had 6 ft. of clarity. The sludge blanket was down. There was little or no floc carryover in the secondary clarifier’s effluent. The chlorine feed rate (as measured by chlorine residual) to the effluent had dropped too. Looking at a sample of mixed liquor under a microscope, there was a healthy biological population. By early afternoon, the chief plant operator decided to reduce the feed rate of
TC 9450 to 12 mg/l and ran the system for another 24 hours. On the 3rd day, they discontinued feeding TC 9450. The DO was back at 3.5 mg/l to 5.0 mg/l. They cut back the operating cycle of the blowers. The settlometer reading was 300 ml at 30 minutes. The effluent turbidity was less than 1.0 NTU, with no settlable solids.

The chief plant operator observed that using TC 9450, the filamentous bacteria population was reduced not eliminated. In publications, studies have shown that having some filamentous bacteria in a wastewater treatment system, benefits the settling of the mixed liquor in secondary clarifiers. However, over population of filamentous bacteria will create “bulking in the clarifier” and floc carryover. In several other studies, ozone was shown to be effective at controlling filamentous bacteria because the singlet oxygen molecule generated by ozone was able to penetrate the multiple layers found in the cell wall of the filamentous bacteria better than chlorine at a lower dosage. The singlet oxygen molecule penetrated the cell membrane, causing the DNA of the nucleus to implode.

The net results of TC4 Solutions’ TC 9450 Liquid Ozone Treating Filamentous Bacteria Bulking were:
No State Regulatory Violations
The plant’s problem was turned around in 24 hours.
There were no overtime costs or additional expenses.
The plant had a cost effective solution to control bulking.

After the plant process was stabilized, the chief plant operator did a cost analysis on using
TC 9450 vs. sodium hypochlorite:

Current Program
Product: Na-Cl2
Dosage: 900 mg/l
Cost: $1275*

Proposed Program
Product: TC 9450
Dosage: 37 mg/l
Cost: $640**

Costs not included in this calculation:
Cost to haul in seeding stock-$600 per truckload (Average 2-3 truckloads)
Plant Violation- $5,000 per day to $25,000 per incident
Plant Operation-extra lab, man-hours at plant and reprocessing wastewater

*sodium hypochlorite (12.5% active)- $1.70/gal (250 gal tote bins)
**TC 9450 (100% active)- $18/gal (55 gal drum)

Based on the results from this short test, if you see poor settling in your clarifier or you notice excessive foam, we recommend testing TC 9450 to help you gain control of your biological process.

For more information on TC 9450, please contact TC4 Solutions, Inc.:
Phone: 302-476-9030 or email: sales@tc4solutions.com.